Troubleshooting of full color LED display screen system

1,055 views admin 2018-08-17

Shenzhen Sunrise Photoelectric Technology is a LED display panel manufacturer, providing integrated production and sales services, the company is located in Pinghu, Shenzhen, plant covers an area of 12,000 square meters, advanced production line equipment, a professional production team and sales team. The factory's LED display has high performance and patience, and its products are certified by ROSH, CE and so on. Exports are widely used in many countries. full color LED display screen In the process of using full color LED display screen equipment, it is inevitable that sometimes there will be problems. Today, we will introduce how to distinguish and judge the fault diagnosis method of full color LED display screen. Step 1: Check whether the graphics card settings are set, according to the needs of the settings method in the CD-ROM electronic file, please consult. Step 2: Check the basic connection of the system, such as DVI cable, network cable socket is correct, the main control card and computer PCI cable connection, serial connection, etc., connection method has legend, please consult carefully. The third step: check the computer and LED power system to meet the needs. When the power supply of the full color LED display screen panel is insufficient, when the display is close to the white (power consumption) will cause the screen to flicker, according to the power supply requirements of the box to prepare the appropriate power supply. Step 4: Check if the green light of the sending card flickers regularly, flicker to step 6. If it doesn't flicker, restart, check if the green light flickers regularly before going into win98/2k/xp. If flickering to the second step, please check if the DVI line is connected properly, if the problem is not solved for the sending card, video card and DVI line. Once there is a fault, please repeat third steps after each replacement. Step 5: Set it up or reinstall it according to the software instructions until the green light flashes, otherwise repeat step 3. Step 6: Check whether the receiving card green light (data lamp) flickers synchronously with the sending card green light. If the flicker turns to step 8, check whether the red light (power supply) is on. If turn on step 7, check whether the yellow light (power protection) is on, if not turn on, check whether the power supply is connected to the reverse or no power output, if turn on, check whether the power supply voltage is 5V, such as Turn off the power supply, remove the adapter card and arrange the wiring to try again, if the problem is not solved for the receiving card fault, replace the receiving card, repeat step 6. Step 7: Check whether the network cable is well connected or too long (must use standard super-5 type network cable, no repeater network wire maximum distance is less than 100 meters), check whether the network cable is made according to the standard (please consult the installation and settings), if the problem is not solved for the receiving card fault, replace the receiving card, repeat step 6. full color LED display screen Step 8: Check whether the large screen power supply lamp is on, if not turn on step 7, check whether the adapter card interface definition line matches the unit board. Note: After most screens are connected, there may be no screen or flower screen in a certain part of the box. Because the RJ45 interface of the network line is not firmly connected, or the power supply of the receiving card is not connected, the signal is not transmitted, so please unplug the network line (or change), or plug in the power supply of the receiving card (attention direction) can be solved. The problem. After reading the above introduction, I believe that we must be more interested in how to diagnose and deal with LED display failure!

Technology | analysis of naked eye 3D display technology

At present, the naked eye 3D large screen market is hot, and 3D technology is also known as 3D di...

Do you like ?1,417 views

Read more

Sunrise’s p2.604 curved LED display lights up under the Eiffel Tower

Sunrise’s p2.604 curved LED display lights up under the Eiffel Tower     Sunri...

Do you like ?1,076 views

Read more

Sunrise LED Rocky Rental Series led display for concert

Concert activities are popular in the United States, and sunrise’s products have been wide...

Do you like ?1,540 views

Read more

Sunrise 264 square meters Galaxy 3115 series mesh led facade in Armenia

  Sunrise 264 square meters Galaxy 3115 series mesh led facade in Armenia     Sun...

Do you like ?1,119 views

Read more

Sunrise led presents awards to excellent salesmen!

Doris, as a new salesman, won three orders in two months. It’s great.   Jack, the bu...

Do you like ?942 views

Read more

Our new product, led grow light, PPE reaches 2.6umol/j

640w and 800W full spectrum led grow light   It can be folded for convenient transportatio...

Do you like ?898 views

Read more

The latest project, Saudi Arabia LED MESH FACADE

The latest project, Saudi Arabia LED MESH FACADE. Ultra-high brightness, ultra-light LED display ...

Do you like ?1,451 views

Read more
Technical Support: Magic Lamp